Uploaded image for project: 'Red Hat Process Automation Manager'
  1. Red Hat Process Automation Manager
  2. RHPAM-2706

Smart router cannot connect to the controller

    XMLWordPrintable

Details

    • Bug
    • Resolution: Done
    • Blocker
    • 7.7.0.GA
    • 7.7.0.GA
    • Cloud
    • None
    • OCP 3.11
      template rhpam77-prod.yaml

    • CR1
    • CR1
    • +
    • Hide

      Deploy rhpam77-prod.yaml
      Check Smart router logs => error is repeatedly shown for connecting Smart router to Monitoring console.

      Show
      Deploy rhpam77-prod.yaml Check Smart router logs => error is repeatedly shown for connecting Smart router to Monitoring console.

    Description

      For 7.6 the Smart router deployment on prod template contained KIE_SERVER_CONTROLLER_USER and KIE_SERVER_CONTROLLER_PWD environment variables. These variables are used to connect Smart router to the Monitoring console. However in 7.7 template these environment variables are missing. Therefore Smart router cannot connect to the Monitoring console.

      Attachments

        Issue Links

          Activity

            People

              jcarvaja@redhat.com Jose Carvajal Hilario
              ksuta Karel Suta
              Jose Carvajal Hilario Jose Carvajal Hilario
              Jose Carvajal Hilario Jose Carvajal Hilario
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: