Bug
-
Resolution: Done
-
Major
-
netobserv-1.5-candidate
-
False
-
None
-
False
-
-
-
NetObserv - Sprint 246
-
Important
Description of problem:
Packet drop filters are mismatched for drop cause and state
Steps to Reproduce:
1. Deploy flowcollector with PacketDrop enabled 2. Go to overview page 3. View the drop cause and state panels and filter on any of the seen causes/states
Actual results:
There is filter mismatch causing no results found to be seen on the panels
Expected results:
Panels should be filtered based on that drop cause/state