Enhancement
-
Resolution: Won't Do
-
Major
-
None
-
10.0.0.Final
-
None
If a datasource-class is defined then it takes precedence to create the datasource and as such it can only use connection-properties.
Since there is not a single connection-url property for all drivers, you have to use connection-properties if you are defining the datasource-class.
A warning when the datasource-class is defined but no connection-properties are present should be issued.
- causes
-
JBEAP-7384 When a datasource has no connection-properties and its driver has defined datasource-class a warning should be issued
- Closed
- is related to
-
WFLY-6157 Connection URL ignored for SQL Server datasource
- Closed
-
JBJCA-1320 Unable to create JDBC local datasource without properties on JBoss EAP 7
- Closed