Uploaded image for project: 'WildFly'
  1. WildFly
  2. WFLY-5085

[Migration operation] If connector has set factory-class org.hornetq.core.remoting.impl.netty.NettyConnectorFactory then migration operation does not translate it to Artemis equivalent

    XMLWordPrintable

Details

    • Bug
    • Resolution: Done
    • Major
    • 10.0.0.Beta2
    • 10.0.0.Alpha6
    • JMS
    • None

    Description

      We should migrate configuration like:

      <connector name="myconnector">
      ...
                      <factory-class&gt;org.hornetq.core.remoting.impl.netty.NettyConnectorFactory</factory-class&gt;
                  </connector>
      

      to:

                      <connector name="myconnector" factory-class="org.apache.activemq.artemis.core.remoting.impl.netty.NettyConnector">
      ...
      

      and not to:

                                <connector name="myconnector" factory-class="org.hornetq.core.remoting.impl.netty.NettyConnectorFactory">
      ...
      

      The same holds for InVMConnector.

      Attachments

        Issue Links

          Activity

            People

              jmesnil1@redhat.com Jeff Mesnil
              mnovak1@redhat.com Miroslav Novak
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: