Bug
-
Resolution: Done
-
Major
-
8.0.0.Alpha1
-
None
Interestingly, if the tests are run in the opposite order i.e. alphabetically, one server instance remains running and doesn't shut down.
I have used a workaround for now
+ <!-- Force the order of tests --> + <runOrder>reversealphabetical</runOrder>