connectors and discovery-group-name are alternative attributes of JMS (pooled) connection factories.
If a resource defines one of this attribute, it must be able to "switch" to the other by running a batch command to:
1. undefine the attribute
2. write the value of the other attribute
This currently does not work:
[standalone@localhost:9999 /] batch
[standalone@localhost:9999 / #] /subsystem=messaging/hornetq-server=default/connection-factory=RemoteConnectionFactory:undefine-attribute(name=connector)
#1 /subsystem=messaging/hornetq-server=default/connection-factory=RemoteConnectionFactory:undefine-attribute(name=connector)
[standalone@localhost:9999 / #] /subsystem=messaging/hornetq-server=default/connection-factory=RemoteConnectionFactory:write-attribute(name=discovery-group-name,value=dg-group1)
#2 /subsystem=messaging/hornetq-server=default/connection-factory=RemoteConnectionFactory:write-attribute(name=discovery-group-name,value=dg-group1)
[standalone@localhost:9999 / #] run-batch
{"JBAS014653: Composite operation failed and was rolled back. Steps that failed:" => {"Operation step-1" => "JBAS011630: Alternative attribute of (connector) is already defined."}}
- incorporates
-
WFLY-1941 can not undefine connection-factory's connector attribute
-