Uploaded image for project: 'Weld'
  1. Weld
  2. WELD-767

The qualified observer section is incorrect

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Major Major
    • 1.1.0.CR1
    • 1.0.0.GA
    • Documentation
    • None
    • Documentation (Ref Guide, User Guide, etc.)
    • Low

      The documentation at http://docs.jboss.org/weld/reference/1.0.0/en-US/html/events.html#d0e3980 is incorrect for the way qualified observers work. The related spec section is 10.2.

      The docs say all possible observers with any of the qualifiers will be called, which is incorrect. The full signature including all qualifiers must match for the observer to be invoked.

              jporter@redhat.com Jason Porter
              jporter@redhat.com Jason Porter
              Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

                Created:
                Updated:
                Resolved: