      The aggregator is not seeing all the passes here https://prow.ci.openshift.org/view/gs/test-platform-results/logs/aggregated-aws-ovn-upgrade-4.19-micro-fips-release-openshift-release-analysis-aggregator/1934731026437771264

      [Jira: "kube-apiserver"] can collect apiserver.openshift.io/disruption-actor=poller poller pod logs expand_less 0s
      {Passed 5 times, failed 0 times, skipped 0 times: we require at least 6 attempts to have a chance at success

      But if you look at the job runs, 9 were full success, and if you check the runs and find one missing in the test output, you can see it ran the test in question and everything looks totally healthy.

      https://prow.ci.openshift.org/view/gs/test-platform-results/logs/periodic-ci-openshift-release-master-nightly-4.19-e2e-aws-ovn-upgrade-fips/1934674455418638336

      There is a build11 registry problem suspected and this job is on build11, but we don't see how that relates to the aggregator, so this is a separate bug.