onError substitution doesn't work on v1beta1 API

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Critical Critical
    • Pipelines 1.19.2
    • Pipelines 1.19.0
    • None
    • None
    • False
    • Hide

      None

      Show
      None
    • False
    • fix(pipeline): support variables in onError for pipeline v1beta1

      Description of problem:

      With 1.19.0 variable substitution works with the onError field. However it only works for v1 api version and not v1beta1.

      See https://github.com/tektoncd/pipeline/pull/8931 for the fix

      Workaround is to migrate to v1