      This commit should be added to pipelines 1.6 to make sure taskruns have release set

      https://github.com/tektoncd/pipeline/commit/2bcd2973dcb8bf2da2b48fdac2f47b9e20d2144e 

      What we have observed was high amount of tekton-controller restart:

      oc get pod tekton-pipelines-controller-5f8d78747f-vr5lq -n openshift-pipelines 
      NAME                                           READY   STATUS    RESTARTS        AGE
      tekton-pipelines-controller-5f8d78747f-vr5lq   1/1     Running   715 (26m ago)   3d17h

      Restarting has stopped once annotation was added to 2 taskruns:

      oc edit taskrun run-prod-updater-j9dxq-init-workspace-6r95r -n greenwave-test
      oc edit hello-ht9f7 -n certifcation-qe
      

      Annotation field was completely missing for these 2^^