Uploaded image for project: 'OpenShift Pipelines'
  1. OpenShift Pipelines
  2. SRVKP-2445

pipelines/taskruns are not running

    XMLWordPrintable

Details

    • Bug
    • Resolution: Done
    • Critical
    • Pipelines 1.6.4
    • Pipelines 1.6
    • Tekton Catalog
    • None
    • 2
    • False
    • None
    • False
    • Pipelines Sprint 224, Pipelines Sprint 225, Pipelines Sprint 226, Pipelines Sprint 227

    Description

      This commit should be added to pipelines 1.6 to make sure taskruns have release set

      https://github.com/tektoncd/pipeline/commit/2bcd2973dcb8bf2da2b48fdac2f47b9e20d2144e 

      What we have observed was high amount of tekton-controller restart:

      oc get pod tekton-pipelines-controller-5f8d78747f-vr5lq -n openshift-pipelines 
      NAME                                           READY   STATUS    RESTARTS        AGE
      tekton-pipelines-controller-5f8d78747f-vr5lq   1/1     Running   715 (26m ago)   3d17h

      Restarting has stopped once annotation was added to 2 taskruns:

      oc edit taskrun run-prod-updater-j9dxq-init-workspace-6r95r -n greenwave-test
      oc edit hello-ht9f7 -n certifcation-qe
      

      Annotation field was completely missing for these 2^^

      Attachments

        Activity

          People

            concaf Shubham Minglani
            pntdevops-mdekan Michal Dekan
            Votes:
            0 Vote for this issue
            Watchers:
            4 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: