Bug
-
Resolution: Done-Errata
-
Undefined
-
None
-
rhwa-23.3
-
None
-
None
-
False
-
-
False
-
-
-
Moderate
Description of the problem:
Unable to save NHC CR when the Order field has a default value of "0", remediator is Self Node Remediation. Value "0" looks like empty field for webhook
How reproducible:
100%
Steps to reproduce:
1. Login to web-console
2. Go Compute/NodeHealthChecks - > Create NodeHealthCheck
3. Enter the name of NHC CR
4. Choose 'Use escalating remediations'
5. Add first template with Remediator 'Other' and Order '-1'
6. Press 'Add more'
7. Choose 'Self node remediation' remediator
8. Fill 'Timeout field', leave 'Order' field as 0
10. Fill 'Nodes selector'
11. Press 'Create'
Actual results:
Error "Required value" for field "spec.escalatingRemediations[1].order".
Expected results:
Template saved
- is related to
-
RHWA-254 Add support for remediation escalation field
-
- Closed
-
- links to
-
RHEA-2023:117758
Node Healthcheck Operator 0.6.0
-
RHSA-2023:120469
Node Healthcheck Operator 0.6.1
- mentioned on