Bug
-
Resolution: Unresolved
-
Major
-
rhel-9.7
-
lvm2-2.03.32-3.el10
-
No
-
Important
-
rhel-storage-lvm
-
ssg_platform_storage
-
15
-
3
-
Dev ack
-
False
-
False
-
-
Yes
-
Red Hat Enterprise Linux
-
None
-
Pass
-
Automated
-
Enhancement
-
-
Done
-
Done
-
Done
-
Done
-
-
All
-
Medium
-
None
What were you trying to do that didn't work?
Activate a failed RaidLV with transiently inaccessible devices recurring.
What is the impact of this issue to you?
No data loss.
Please provide the package NVR for which the bug is seen:
How reproducible is this bug?:
Always.
Steps to reproduce
- Create e.g. a raid5 LV
- Fail more than 1 rimage device e.g. by failing the PV(s) backing it.
- Deactivate and try reactivate the RaidLV
- Make the rimage devices failed recur, e.g. all accessible again
- Try reactivating -> failure
Expected results
RaidLV can be reactivated after an "lvconvert --rapair ... $RaidLV"
Actual results
Activation failes.
- clones
-
RHEL-67039 lvm raid: add repair support to allow activation of Raid456LVs with too many transiently failed recurred devices
-
- Release Pending
-
- is blocked by
-
RHEL-70451 [RHEL10.1] Rebase lvm2 to 2.03.29 or later
-
- Release Pending
-
- links to
-
RHBA-2025:151109
lvm2 update