Based on this upstream discussions: https://gitlab.freedesktop.org/NetworkManager/NetworkManager/-/merge_requests/2139 NetworkManager should not prematurely consider OVS interfaces “available” when ovsdb->ready is not yet set to TRUE, but must still allow non-OVS devices (like physical ports in a bond) to activate even if their carrier is down initially. This ticket aims to refine the activation process so OVS interfaces wait until OVSDB is ready while still handling other device types correctly.
- clones
-
RHEL-80157 Improve interface activation logic in NetworkManager
-
- Release Pending
-
- links to
-
RHBA-2025:146814 NetworkManager bug fix and enhancement update