Description of a problem
The values of the attributes nsds5replicaLastInitStart and nsds5replicaLastInitEnd are reset to 19700101000000Z after restating the RHDS instance.
Version-Release number of the selected component
rpm -q 389-ds-base cockpit-389-ds
389-ds-base-1.4.3.37-10.module+el8dsrv+21971+f7435891.x86_64 cockpit-389-ds-1.4.3.37-10.module+el8dsrv+21971+f7435891.noarch
Browser (if applicable)
Steps to reproduce
1. Create a replication agreement between a supplier and a consumer 2. Reinitialize the consumer 3. Check the values of nsds5replicaLastInitStart and nsds5replicaLastInitEnd 4. Restart the supplier 5. Check again the values. They are now reset to epoch ( 19700101000000Z )
Actual results
Replication status information is incorrect.
Expected results
Keep the values of the last initialization start and end.
Additional information
Customers might think that the previous reinitialization actually failed and would attempt to redo it again and again.