What were you trying to do that didn't work?
Previously new instance of app/windows has been opened on the active workspace, new mutter causes window to be opened on a different workspace where first instance of the app has been opened.
Please provide the package NVR for which bug is seen:
mutter-40.9-20.el9 (RHEL 9.5. beta)
How reproducible:
always
Steps to reproduce
- install RHEL9 and update to the latest RHEL9.5 beta incl. mutter-40.9-20.el9
- login as a user into gnome/wayland standard session
- enable "launch new instance" gnome extension
- on workspace 1 start gnome-terminal
- switch to workspace 2
- start gnome-terminal
Expected results
first terminal is opened on workspace 1
second terminal is opened on workspace 2
Actual results
first terminal is opened on workspace 1
after start of second terminal on workspace 2 nothing happens
when you switch back to workspace 1 you see second terminal has been opened there