Bug
-
Resolution: Unresolved
-
Undefined
-
None
-
rhel-10.2
-
None
-
None
-
Moderate
-
rhel-pt-pcp
-
2
-
False
-
False
-
-
None
-
None
-
None
-
None
-
Unspecified
-
Unspecified
-
Unspecified
-
-
All
-
None
pcp2opentelemetry always fails when exporting a metric of type 'counter'.
PCP version: pcp-7.0.3-1.el10
Reproducer:
The following command fails ...
# pcp2opentelemetry -s 1 kernel.all.pswitch
{ "//": "Waiting for 1 metrics to be written to stdout:" }
{ "//": "1 samples(s) with 10.0 sec interval ~ 0 sec runtime." }
ERROR: metric(s) invalid
... even the metric is valid and provides values
# pminfo -fd kernel.all.pswitch
kernel.all.pswitch
Data Type: 64-bit unsigned int InDom: PM_INDOM_NULL 0xffffffff
Semantics: counter Units: count
value 17354830