Story
-
Resolution: Unresolved
-
Normal
-
None
-
device-mapper-multipath-0.9.9-15.el10
-
Low
-
rhel-storage-dm
-
11
-
15
-
None
-
False
-
False
-
-
No
-
None
-
Requested
-
None
-
Release Note Not Required
-
-
Proposed
-
Unspecified
-
Unspecified
-
Unspecified
-
None
I was requested by the support specialist to raise this ticket to Red Hat Engineering team.
We are asking to update the Infinidat storage array device stanza in the /etc/multipath.conf to the following one :
device {
vendor "NFINIDAT"
product "InfiniBox"
path_grouping_policy "group_by_prio"
path_checker "tur"
features 0
hardware_handler "1 alua"
prio "alua"
rr_weight "priorities"
no_path_retry "queue"
rr_min_io 1
rr_min_io_rq 1
flush_on_last_del "yes"
fast_io_fail_tmo 15
dev_loss_tmo "infinity"
path_selector "service-time 0"
failback "immediate"
detect_prio "no"
user_friendly_names "no"
}
Please update the default configuration in RHEL version: 8, 9, and 10.
The customer support ticket :
https://access.redhat.com/support/cases/#/case/04303359
Case Title: Include updated multipath.conf entry for Infinidat storage
Case Number : 04303359
Case Open Date : 2025-11-10 13:06:24