What were you trying to do that didn't work?
When using `sg3_utils`, it is supposed to display the Unit Serial Number (USN)
What is the impact of this issue to you?
The `sg3_utils` package no longer displays the Unit Serial Number (USN) for ATA devices on RHEL10, causing issues with old monitoring scripts
Please provide the package NVR for which the bug is seen:
`sg3_utils` on RHEL10
How reproducible is this bug?:
Just us the command:
# sg_inq /dev/<device_block>
Steps to reproduce
Use the command on RHEL 10
# sg_inq /dev/<device_block>
Expected results
It should show to USN ( Unit Serial Number ) like from the older RHEL versions
# sg_inq /dev/sda
Vendor identification: ATA
Product identification: TOSHIBA MG10AFA2
Product revision level: 0103
Unit Serial Number: 94G0A05MFM8J
Actual results
It's missing the USN on RHEL 10
# sg_inq /dev/sda Vendor identification: ATA Product identification: TOSHIBA MG10AFA2 Product revision level: 0103
Additional Information
If you can see, they have reverted it in commit 7fbb2a5 from the sg3_utils GitHub