Uploaded image for project: 'Red Hat OpenStack Services on OpenShift'
  1. Red Hat OpenStack Services on OpenShift
  2. OSPRH-2808

BZ#2245300 Manual sync misidentifies Octavia OVN Load Balancer health monitor port and deletes metadata port

XMLWordPrintable

    • False
    • Hide

      None

      Show
      None
    • False
    • Committed
    • Not Set
    • Not Set
    • No
    • 2024Q3
    • Important

      +++ This bug was initially created as a clone of Bug #2244631 +++

      Description of problem:
      Doing manual ovn sync:
      neutron-ovn-db-sync-util --config-file=/etc/neutron/neutron.conf --config-file=/etc/neutron/plugins/ml2/ml2_conf.ini --ovn-neutron_sync_mode repair

      Misidentifies Octavia OVN Load Balancer Health Monitor Port and Deletes Metadata Port:

      47:2023-09-28 13:22:29.565 2053 WARNING neutron.plugins.ml2.drivers.ovn.mech_driver.ovsdb.ovn_db_sync [req-b037dd97-5936-4981-b0be-d4c88c6e806d - - - - -] Unnecessary DHCP port 77cc790a-1712-4fc2-b184-918842588a06 for network dd8dbcd7-0f6f-424f-aa2e-256630af44fd found in Neutron
      48:2023-09-28 13:22:29.565 2053 WARNING neutron.plugins.ml2.drivers.ovn.mech_driver.ovsdb.ovn_db_sync [req-b037dd97-5936-4981-b0be-d4c88c6e806d - - - - -] Deleting unnecessary DHCP port 77cc790a-1712-4fc2-b184-918842588a06 for network dd8dbcd7-0f6f-424f-aa2e-256630af44fd

      OVN LB health monitor port got .3 IP, and metadata uses it now as its port:

      ip netns exec ovnmeta-dd8dbcd7-0f6f-424f-aa2e-256630af44fd ip a
      1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
      link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
      inet 127.0.0.1/8 scope host lo
      valid_lft forever preferred_lft forever
      inet6 ::1/128 scope host
      valid_lft forever preferred_lft forever
      2: tapdd8dbcd7-01@if2868: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
      link/ether fa:16:3e:c9:12:45 brd ff:ff:ff:ff:ff:ff link-netnsid 0
      inet 169.254.169.254/32 brd 169.254.169.254 scope global tapdd8dbcd7-01
      valid_lft forever preferred_lft forever
      inet 192.168.100.3/24 brd 192.168.100.255 scope global tapdd8dbcd7-01
      valid_lft forever preferred_lft forever

      openstack port show ovn-lb-hm-b7383d04-9220-48cd-bac9-3e2c53ad2d5f
      -----------------------------------------------------------------------------------------------------+

      Field Value

      -----------------------------------------------------------------------------------------------------+

      admin_state_up UP
      allowed_address_pairs  
      binding_host_id  
      binding_profile  
      binding_vif_details  
      binding_vif_type unbound
      binding_vnic_type normal
      created_at 2023-09-14T12:30:30Z
      data_plane_status None
      description  
      device_id  
      device_owner network:distributed
      device_profile None
      dns_assignment None
      dns_domain None
      dns_name None
      extra_dhcp_opts  
      fixed_ips ip_address='192.168.100.3', subnet_id='b7383d04-9220-48cd-bac9-3e2c53ad2d5f'
      id 2831bc8f-60e4-4a44-88e1-f3010cce3cbd
      ip_allocation None
      mac_address fa:16:3e:c9:12:45
      name ovn-lb-hm-b7383d04-9220-48cd-bac9-3e2c53ad2d5f
      network_id dd8dbcd7-0f6f-424f-aa2e-256630af44fd
      numa_affinity_policy None
      port_security_enabled False
      project_id e4529e5a687e4128af2935fb33cfa7c2
      propagate_uplink_status None
      qos_network_policy_id None
      qos_policy_id None
      resource_request None
      revision_number 1
      security_group_ids  
      status DOWN
      tags  
      trunk_details None
      updated_at 2023-09-14T12:30:30Z

      -----------------------------------------------------------------------------------------------------+

      Workaround - removed health monitor, readded manually ovnmeta port, restart metadata agents.

      Version-Release number of selected component (if applicable):

      How reproducible:
      Easily having a OVN LB HM port with device_owner=network:distributed and another ovn-metadata ports.

      Steps to Reproduce:
      1. Create a OVN LB Health monitor
      2. Run neutron-db-sync tool

      Actual results:
      OVN-metadata port will dissapear if its uuid is "bigger" than the OVN LB HM port uuid.

      Expected results:
      OVN metadata and OVN LB HM port are not deleted.

      — Additional comment from RHEL Program Management on 2023-10-17 12:51:28 UTC —

      This item has been properly Triaged and planned for the release, and Target Release is now set to match the release flag.

              froyo@redhat.com Fernando Royo
              jira-bugzilla-migration RH Bugzilla Integration
              Bruna Bonguardo Bruna Bonguardo
              rhos-dfg-networking-squad-vans
              Votes:
              0 Vote for this issue
              Watchers:
              3 Start watching this issue

                Created:
                Updated:
                Resolved: