Uploaded image for project: 'OPCT - OpenShift Provider Compatibility Tool'
  1. OPCT - OpenShift Provider Compatibility Tool
  2. OPCT-242

[doc] Disconnected guide is missing one image to mirror

XMLWordPrintable

    • False
    • Hide

      None

      Show
      None
    • False

      Goal:

      • Fix the Disconnected documentation[1] adding a missing image to mirror required by openshift-tests utility. CI reference[2]

      Errors in the plugin runtime:

      Aug 3 14:02:10.082: INFO: At 2023-08-03 13:59:46 +0000 UTC - event for filler-pod-17d19f1d-20f2-43b6-b9fa-2d0428d8f6a5: {kubelet manta-dev-rlznz-worker-7r9zl} Failed: Error: ImagePullBackOff
      Aug 3 14:02:10.082: INFO: At 2023-08-03 13:59:46 +0000 UTC - event for filler-pod-17d19f1d-20f2-43b6-b9fa-2d0428d8f6a5: {kubelet manta-dev-rlznz-worker-7r9zl} BackOff: Back-off pulling image "registry.example.com:5050/ocp-cert:e2e-28-registry-k8s-io-pause-3-8-aP7uYsw5XCmoDy5W" 

      Quick solution:

      oc image mirror --registry-config ~/Installs/pullsecret registry.k8s.io/pause:3.8  registry.example.com:5050/ocp-cert:e2e-28-registry-k8s-io-pause-3-8-aP7uYsw5XCmoDy5W  

      [1] https://redhat-openshift-ecosystem.github.io/provider-certification-tool/user-installation-disconnected/#configuring-the-disconnected-mirror-registry

      [2] https://github.com/openshift/release/blob/master/ci-operator/step-registry/baremetalds/e2e/test/baremetalds-e2e-test-commands.sh#L22

              rhn-support-mrbraga Marco Braga
              rhn-support-mrbraga Marco Braga
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

                Created:
                Updated:
                Resolved: