Description of problem:
Though iDRAC 10 firmware updates succeeded, oc describe shows servicing error. in addition, node did not return to Ready state:
Normal PowerOff 52m metal3-baremetal-controller Host soft powered off
Normal ServicingError 43m metal3-baremetal-controller Node 68a7d19d-ebc0-42b6-8599-4c36a05a0bd8 failed step {'args': {'settings': [{'component': 'bmc', 'url': 'http://fw.apps.jhajyahy-vv.qe.devcluster.openshift.com/firmimg.d10'}]}, 'interface': 'firmware', 'step': 'update', 'abortable': False, 'priority': 0}: HTTP GET https://10.26.16.132/redfish/v1/ returned code 503. Base.1.18.GeneralError: The service is temporarily unavailable. Retry in 30 seconds. Extended information: [{'MessageId': 'Base.1.18.ServiceTemporarilyUnavailable', 'MessageArgs': ['30'], 'RelatedProperties': [], 'Message': 'The service is temporarily unavailable. Retry in 30 seconds.', 'Severity': 'Critical', 'Resolution': 'Wait for the indicated retry duration and retry the operation.'}]. Also failed to tear down servicing.
Version-Release number of selected component (if applicable):
How reproducible:
Steps to Reproduce:
1. Perform FW update on IDRAC 10 server using HFC
2. Check "oc describe bmh -n openshift-machine-api <host>" command output
3.
Actual results:
passed with servicing errors
Expected results:
To pass without servicing errors
Additional info: