      Description of problem:

      When node goes unhealthy (kubelet.service is stopped), it's marked at unhealthy but nothing goes past that

      Version-Release number of selected component (if applicable):

      ocp 4.12

      How reproducible:

      100%

      Steps to Reproduce:

      1.Create MHC CR with machine.openshift.io/remediation-strategy: external-baremetal annotation and unhealthy conditions:
      Unhealthy Conditions:
          Status:   False
          Timeout:  60s
          Type:     Ready
          Status:   Unknown
          Timeout:  60s
          Type:     Ready
      2.Stop kubelet.service on node to trigger unhealthy condition
      3.Wait till remediation starts
      

      Actual results:

      Node is stuck with NotReady status

      Expected results:

      Node is rebooted and is added to cluster

      Additional info:

       

            imelofer Iury Gregory Melo Ferreira
            vsibirsk Vasiliy Sibirskiy
            Pedro Jose Amoedo Martinez Pedro Jose Amoedo Martinez
            Vasiliy Sibirskiy
            Votes:
            0 Vote for this issue
            Watchers:
            10 Start watching this issue

              Created:
              Updated:
              Resolved: