Description of problem:
In the PTP ntpfailover plugin, chronyc offline is only run during state transitions based on ts2phc logs. Any restart of the chronyd process will then start back up with sources online and updating the system clock. It will only be disabled again if a transition to failover and back occurs, not when the process is started again
Version-Release number of selected component (if applicable):
ose-linuxptp-daemon-container-v4.21.0-202511201708.p2.gadc7320.assembly.stream.el9
How reproducible:
100%
Steps to Reproduce:
1. Enabled the ntpfailover plugin on a GM profile and reach a steady state
2. pkill chronyd in the linuxptp-daemon-container
3. Run chronyc activity to see online sources
Actual results:
sources online
Expected results:
0 sources online
Additional info: