Description of problem:
The clock class doesn't return to Locked (6) from a degraded clock class (135, 165, 248).
Version-Release number of selected component (if applicable):
ptp-operator.v4.20.0-202508140915
How reproducible:
100%
Steps to Reproduce:
1.Cause a loss of upstream clock by taking down the upstream interface connection; ip link set ens2f3 down. 2.Clock Class downgrades. 3.Recover upstream interface; ip link set ens2f3 up.
Actual results:
Clock Class remains on the last class; e.g. Clock Class degraded to 135, upstream clock connection resumes, Clock Class remains on 135.
Expected results:
Clock Class returns to locked class; e.g. Clock Class degraded to 135, upstream clock connection resumes, Clock Class turns back to 6.
Additional info:
- links to