Description of problem:
level=debug msg=ironic_node_v1.openshift-master-host[2]: Still creating... [4m50s elapsed]
level=error
level=error msg=Error: could not inspect: could not inspect node, node is currently 'inspect failed' , last error was 'Failed to inspect hardware. Reason: unable to start inspection: HTTP POST https://10.46.98.49:443/redfish/v1/Managers/iDRAC.Embedded.1/VirtualMedia/CD/Actions/VirtualMedia.EjectMedia returned code 500. Base.1.8.GeneralError: Unable to disconnect Virtual Media devices. Extended information: [{'Message': 'Unable to disconnect Virtual Media devices.', 'MessageArgs': [], 'MessageArgs@odata.count': 0, 'MessageId': 'IDRAC.2.6.VRM0010', 'RelatedProperties': [], 'RelatedProperties@odata.count': 0, 'Resolution': 'No response action is required.', 'Severity': 'Critical'}, {'Message': 'The request failed due to an internal service error. The service is still operational.', 'MessageArgs': [], 'MessageArgs@odata.count': 0, 'MessageId': 'Base.1.8.InternalError', 'RelatedProperties': [], 'RelatedProperties@odata.count': 0, 'Resolution': 'Resubmit the request. If the problem persists, consider resetting the service.', 'Severity': 'Critical'}]'
level=error
level=error msg= with ironic_node_v1.openshift-master-host[0],
level=error msg= on main.tf line 13, in resource "ironic_node_v1" "openshift-master-host":
level=error msg= 13: resource "ironic_node_v1" "openshift-master-host" {
level=error
level=error
In this case there is CD mapped
[root@ocp-edge111# ~]$ curl -u root:calvin -k https://10.46.98.49:443/redfish/v1/Managers/iDRAC.Embedded.1/VirtualMedia/CD/Actions/VirtualMedia.EjectMedia -d '{}' -X POST -H 'Content-Type: application/json' | jq
% Total % Received % Xferd Average Speed Time Time Time Current
Dload Upload Total Spent Left Speed
100 2 0 0 100 2 0 1 0:00:02 0:00:01 0:00:01 1
Immediately after I disconnect the CD with the first command I ran this command again and got error
[root@ocp-edge111# ~]$ curl -u root:calvin -k https://10.46.98.49:443/redfish/v1/Managers/iDRAC.Embedded.1/VirtualMedia/CD/Actions/VirtualMedia.EjectMedia -d '{}' -X POST -H 'Content-Type: application/json' | jq
% Total % Received % Xferd Average Speed Time Time Time Current
Dload Upload Total Spent Left Speed
100 775 100 773 100 2 2393 6 --:--:-- --:--:-- --:--:-- 2391
{
"error": {
"@Message.ExtendedInfo": [
{
"Message": "No Virtual Media devices are currently connected.",
"MessageArgs": [],
"MessageArgs@odata.count": 0,
"MessageId": "IDRAC.2.6.VRM0009",
"RelatedProperties": [],
"RelatedProperties@odata.count": 0,
"Resolution": "No response action is required.",
"Severity": "Critical"
},
{
"Message": "The request failed due to an internal service error. The service is still operational.",
"MessageArgs": [],
"MessageArgs@odata.count": 0,
"MessageId": "Base.1.8.InternalError",
"RelatedProperties": [],
"RelatedProperties@odata.count": 0,
"Resolution": "Resubmit the request. If the problem persists, consider resetting the service.",
"Severity": "Critical"
}
],
"code": "Base.1.8.GeneralError",
"message": "A general error has occurred. See ExtendedInfo for more information"
}
}
Version-Release number of selected component (if applicable):
"Dell": {
"@odata.type": "#DellOem.v1_2_0.DellOemResources",
"DelliDRACCard": {
"@odata.context": "/redfish/v1/$metadata#DelliDRACCard.DelliDRACCard",
"@odata.id": "/redfish/v1/Managers/iDRAC.Embedded.1/Oem/Dell/DelliDRACCard/iDRAC.Embedded.1-1_0x23_IDRACinfo",
"@odata.type": "#DelliDRACCard.v1_1_0.DelliDRACCard",
"Description": "An instance of DelliDRACCard will have data specific to the Integrated Dell Remote Access Controller (iDRAC) in the managed system.",
"IPMIVersion": "2.0",
"Id": "iDRAC.Embedded.1-1_0x23_IDRACinfo",
"LastSystemInventoryTime": "2022-12-13T20:00:15+00:00",
"LastUpdateTime": "2022-12-13T20:34:36+00:00",
"Name": "DelliDRACCard",
"URLString": "https://:443"
"FirmwareVersion": "5.10.50.00",
How reproducible:
Try to deploy the install-config.yaml on the Dell iDRAC (PowerEdge R650xs)
Steps to Reproduce:
1.Try to deploy the install-config.yaml on the Dell iDRAC (PowerEdge R650xs) 2. 3.
Actual results:
could not inspect: could not inspect node, node is currently 'inspect failed' , last error was 'Failed to inspect hardware. Reason: unable to start inspection: HTTP POST https://10.46.98.49:443/redfish/v1/Managers/iDRAC.Embedded.1/VirtualMedia/CD/Actions/VirtualMedia.EjectMedia returned code 500. Base.1.8.GeneralError: Unable to disconnect Virtual Media devices. Extended information: [{'Message': 'Unable to disconnect Virtual Media devices.', 'MessageArgs': [], 'MessageArgs@odata.count': 0, 'MessageId': 'IDRAC.2.6.VRM0010', 'RelatedProperties': [], 'RelatedProperties@odata.count': 0, 'Resolution': 'No response action is required.', 'Severity': 'Critical'}, {'Message': 'The request failed due to an internal service error. The service is still operational.', 'MessageArgs': [], 'MessageArgs@odata.count': 0, 'MessageId': 'Base.1.8.InternalError', 'RelatedProperties': [], 'RelatedProperties@odata.count': 0, 'Resolution': 'Resubmit the request. If the problem persists, consider resetting the service.', 'Severity': 'Critical'}]'
Expected results:
Disk eject
Additional info: