Bug
-
Resolution: Unresolved
-
Undefined
-
None
-
4.17.0
-
None
This is a clone of issue OCPBUGS-43108. The following is the description of the original issue:
—
This is a clone of issue OCPBUGS-41897. The following is the description of the original issue:
—
Description of problem:
Unable to Recreate Default SriovOperatorConfig
Version-Release number of selected component (if applicable):
4.17.0-rc.2
sriov-network-operator.v4.17.0-202409100034
How reproducible:
100%
Steps to Reproduce:
- Apply the default SriovOperatorConfig.
- Remove the default SriovOperatorConfig.
- Apply it again.
Actual results:
$ oc apply -f /tmp/opconfig.yml Error from server (InternalError): error when creating "/tmp/opconfig.yml": Internal error occurred: failed calling webhook "operator-webhook.sriovnetwork.openshift.io": failed to call webhook: Post "https://operator-webhook-service.openshift-sriov-network-operator.svc:443/validating-custom-resource?timeout=10s": service "operator-webhook-service" not found
Expected results:
Recreated successfully
Additional info:
- clones
-
OCPBUGS-43108 SR-IOV: Unable to Recreate Default SriovOperatorConfig
- Closed
- is blocked by
-
OCPBUGS-43108 SR-IOV: Unable to Recreate Default SriovOperatorConfig
- Closed
- links to