Description of problem:
Sriov-network-operator controller does not detect changes to the machine config when the files within the Sriov-network-operator controller pod are different then the rendered machine config in OCP.
Version-Release number of selected component (if applicable):
How reproducible:
Always
Steps to Reproduce:
1. Change a file in /bindata/manifests 2. Compile the sriov-network-operator controller 3. Load the new controller. 4. You will get "syncOvsHardwareOffloadMachineConfigs No content change, skip updating MC" in the logs when the machine config should have changed.
Actual results:
Machine Config is not updated on the nodes.
Expected results:
Machine Config is updated on the nodes.
Additional info:
- clones
-
OCPBUGS-4140 [4.12] Sriov-network-operator does not detect changes to Machine Config (when updating the machine config)
-
- Closed
-
- depends on
-
OCPBUGS-4392 [4.9.z] Sriov-network-operator does not detect changes to Machine Config (when updating the machine config)
-
- Closed
-