      Component Readiness has found a potential regression in the following test:

      [sig-mco][OCPFeatureGate:ManagedBootImages][Serial] Should degrade on a MachineSet with an OwnerReference [apigroup:machineconfiguration.openshift.io] [Suite:openshift/conformance/serial]

      New feature went live that ensures new tests in a release have at least a 95% pass rate. This test was one that showed up immediately with a couple bad runs in the last 20 attempts. The failures look similar which indicate the test probably has a problem that could be fixed.

      We suspect a timeout issue, the test takes about 25s on average with a 30s timeout.

      Test has a 91.67% pass rate, but 95.00% is required.

      Sample (being evaluated) Release: 4.18
      Start Time: 2024-10-10T00:00:00Z
      End Time: 2024-10-17T23:59:59Z
      Success Rate: 91.67%
      Successes: 22
      Failures: 2
      Flakes: 0

      Insufficient pass rate

      View the test details report at https://sippy.dptools.openshift.org/sippy-ng/component_readiness/test_details?Aggregation=none&Architecture=amd64&Architecture=amd64&FeatureSet=default&FeatureSet=default&Installer=ipi&Installer=ipi&Network=ovn&Network=ovn&NetworkAccess=default&Platform=gcp&Platform=gcp&Scheduler=default&SecurityMode=default&Suite=serial&Suite=serial&Topology=ha&Topology=ha&Upgrade=none&Upgrade=none&baseEndTime=2024-10-01%2023%3A59%3A59&baseRelease=4.17&baseStartTime=2024-09-01%2000%3A00%3A00&capability=OCPFeatureGate%3AManagedBootImages&columnGroupBy=Architecture%2CNetwork%2CPlatform&component=Machine%20Config%20Operator&confidence=95&dbGroupBy=Platform%2CArchitecture%2CNetwork%2CTopology%2CFeatureSet%2CUpgrade%2CSuite%2CInstaller&environment=amd64%20default%20ipi%20ovn%20gcp%20serial%20ha%20none&ignoreDisruption=true&ignoreMissing=false&includeVariant=Architecture%3Aamd64&includeVariant=CGroupMode%3Av2&includeVariant=ContainerRuntime%3Arunc&includeVariant=FeatureSet%3Adefault&includeVariant=Installer%3Aipi&includeVariant=Installer%3Aupi&includeVariant=Owner%3Aeng&includeVariant=Platform%3Aaws&includeVariant=Platform%3Aazure&includeVariant=Platform%3Agcp&includeVariant=Platform%3Ametal&includeVariant=Platform%3Avsphere&includeVariant=Topology%3Aha&minFail=3&passRateAllTests=0&passRateNewTests=95&pity=5&sampleEndTime=2024-10-17%2023%3A59%3A59&sampleRelease=4.18&sampleStartTime=2024-10-10%2000%3A00%3A00&testId=openshift-tests%3A94bbe8be59569d92f1c5afdef12b26dd&testName=%5Bsig-mco%5D%5BOCPFeatureGate%3AManagedBootImages%5D%5BSerial%5D%20Should%20degrade%20on%20a%20MachineSet%20with%20an%20OwnerReference%20%5Bapigroup%3Amachineconfiguration.openshift.io%5D%20%5BSuite%3Aopenshift%2Fconformance%2Fserial%5D