Description of problem: After migrating cluster from SDN to OVN, seeing intermittent failures while accessing service.
Wed Jul 31 05:28:11 UTC 2024 Wed Jul 31 01:28:11 EDT 2024 Hello OpenShift! Wed Jul 31 05:28:42 UTC 2024 Wed Jul 31 01:28:42 EDT 2024 curl: (7) Failed to connect to 34.92.142.227 port 27018 after 75006 ms: Couldn't connect to server Wed Jul 31 05:30:27 UTC 2024 Wed Jul 31 01:30:27 EDT 2024 Hello OpenShift! Wed Jul 31 05:31:59 UTC 2024 Wed Jul 31 01:31:59 EDT 2024 Hello OpenShift! Wed Jul 31 05:33:31 UTC 2024 Wed Jul 31 01:33:31 EDT 2024 Hello OpenShift! Wed Jul 31 05:34:01 UTC 2024 Wed Jul 31 01:34:01 EDT 2024 curl: (52) Empty reply from server Wed Jul 31 05:38:51 UTC 2024 Wed Jul 31 01:38:51 EDT 2024 Hello OpenShift!
Version-Release number of selected component (if applicable):
$ oc version Client Version: 4.15.14 Kustomize Version: v5.0.4-0.20230601165947-6ce0bf390ce3 Server Version: 4.15.0-0.nightly-2024-07-29-053620 Kubernetes Version: v1.28.11+add48d0*no* further _formatting_ is done here
How reproducible:
Steps to Reproduce:
1. Create a 4.14 SDN OSD on GCP cluster
2. Upgrade to 4.15
3. Scale cluster to 24 nodes
4. Add cluster-density-v2 workload
5. Run migration and let if finish
6. Start seeing errors
Actual results: Intermittent failures accessing service.
Expected results: Live migration should not cause disruption to service.
Additional info:
Please fill in the following template while reporting a bug and provide as much relevant information as possible. Doing so will give us the best chance to find a prompt resolution.
Affected Platforms:
Is it an
- internal CI failure
- customer issue / SD
- internal RedHat testing failure
If it is an internal RedHat testing failure:
- Please share a kubeconfig or creds to a live cluster for the assignee to debug/troubleshoot along with reproducer steps (specially if it's a telco use case like ICNI, secondary bridges or BM+kubevirt).
If it is a CI failure:
- Did it happen in different CI lanes? If so please provide links to multiple failures with the same error instance
- Did it happen in both sdn and ovn jobs? If so please provide links to multiple failures with the same error instance
- Did it happen in other platforms (e.g. aws, azure, gcp, baremetal etc) ? If so please provide links to multiple failures with the same error instance
- When did the failure start happening? Please provide the UTC timestamp of the networking outage window from a sample failure run
- If it's a connectivity issue,
- What is the srcNode, srcIP and srcNamespace and srcPodName?
- What is the dstNode, dstIP and dstNamespace and dstPodName?
- What is the traffic path? (examples: pod2pod? pod2external?, pod2svc? pod2Node? etc)
If it is a customer / SD issue:
- Provide enough information in the bug description that Engineering doesn’t need to read the entire case history.
- Don’t presume that Engineering has access to Salesforce.
- Do presume that Engineering will access attachments through supportshell.
- Describe what each relevant attachment is intended to demonstrate (failed pods, log errors, OVS issues, etc).
- Referring to the attached must-gather, sosreport or other attachment, please provide the following details:
- If the issue is in a customer namespace then provide a namespace inspect.
- If it is a connectivity issue:
- What is the srcNode, srcNamespace, srcPodName and srcPodIP?
- What is the dstNode, dstNamespace, dstPodName and dstPodIP?
- What is the traffic path? (examples: pod2pod? pod2external?, pod2svc? pod2Node? etc)
- Please provide the UTC timestamp networking outage window from must-gather
- Please provide tcpdump pcaps taken during the outage filtered based on the above provided src/dst IPs
- If it is not a connectivity issue:
- Describe the steps taken so far to analyze the logs from networking components (cluster-network-operator, OVNK, SDN, openvswitch, ovs-configure etc) and the actual component where the issue was seen based on the attached must-gather. Please attach snippets of relevant logs around the window when problem has happened if any.
- When showing the results from commands, include the entire command in the output.
- For OCPBUGS in which the issue has been identified, label with “sbr-triaged”
- For OCPBUGS in which the issue has not been identified and needs Engineering help for root cause, label with “sbr-untriaged”
- Do not set the priority, that is owned by Engineering and will be set when the bug is evaluated
- Note: bugs that do not meet these minimum standards will be closed with label “SDN-Jira-template”
- For guidance on using this template please see
OCPBUGS Template Training for Networking components
- clones
-
OCPBUGS-37855 Post SDN to OVN live migration shows intermittent service connectivity failures for OSD on GCP cluster
- Closed
- is cloned by
-
OCPBUGS-38697 Post SDN to OVN live migration shows intermittent service connectivity failures for OSD on GCP cluster
- Closed
- is depended on by
-
OCPBUGS-38697 Post SDN to OVN live migration shows intermittent service connectivity failures for OSD on GCP cluster
- Closed
- links to