Description of problem:
On an SNO with Telco DU profile linuxptp-daemon reports timed out while polling for tx timestamp errors: oc -n openshift-ptp logs linuxptp-daemon-9fdbz -c linuxptp-daemon-container | grep 'timed' ptp4l[46803.358]: [ptp4l.0.config] timed out while polling for tx timestamp phc2sys[46803.194]: [ptp4l.0.config] CLOCK_REALTIME rms 4 max 4 freq -9153 +/- 0 delay 493 +/- 0 ptp4l[46803.227]: [ptp4l.0.config] master offset 3 s2 freq -14064 path delay 1084 ptp4l[46803.358]: [ptp4l.0.config] timed out while polling for tx timestamp ptp4l[46803.358]: [ptp4l.0.config] port 1: clearing fault immediately ptp4l[46803.358]: [ptp4l.0.config] increasing tx_timestamp_timeout may correct this issue, but it is likely caused by a driver bug ptp4l[46803.358]: [ptp4l.0.config] port 1: send delay request failed ptp4l[46803.400]: [ptp4l.0.config] port 1: SLAVE to LISTENING on INIT_COMPLETE ptp4l[46803.434]: [ptp4l.0.config] port 1: new foreign master b47af1.fffe.7b20e2-1 ptp4l[46803.684]: [ptp4l.0.config] port 1: LISTENING to UNCALIBRATED on RS_SLAVE ptp4l[46803.728]: [ptp4l.0.config] master offset 10 s2 freq -14052 path delay 1085 ptp4l[46803.728]: [ptp4l.0.config] port 1: UNCALIBRATED to SLAVE on MASTER_CLOCK_SELECTED ptp4l[46803.791]: [ptp4l.0.config] master offset -1 s2 freq -14070 path delay 1085 ptp4l[46803.853]: [ptp4l.0.config] master offset 12 s2 freq -14048 path delay 1084 ptp4l[46803.916]: [ptp4l.0.config] master offset 0 s2 freq -14067 path delay 1084 ptp4l[46803.978]: [ptp4l.0.config] master offset 12 s2 freq -14047 path delay 1084 ptp4l[46804.041]: [ptp4l.0.config] master offset -4 s2 freq -14073 path delay 1084 ptp4l[46804.103]: [ptp4l.0.config] master offset -7 s2 freq -14078 path delay 1084 ptp4l[46804.166]: [ptp4l.0.config] master offset 4 s2 freq -14060 path delay 1086 phc2sys[46804.194]: [ptp4l.0.config] port b49691.fffe.a57b06-1 changed state phc2sys[46804.194]: [ptp4l.0.config] port b49691.fffe.a57b06-1 changed state phc2sys[46804.194]: [ptp4l.0.config] port b49691.fffe.a57b06-1 changed state phc2sys[46804.194]: [ptp4l.0.config] reconfiguring after port state change phc2sys[46804.194]: [ptp4l.0.config] selecting CLOCK_REALTIME for synchronization phc2sys[46804.195]: [ptp4l.0.config] selecting ens2f2 as the master clock
Version-Release number of selected component (if applicable):
4.12.0-rc.0 ptp-operator.4.11.0-202210262118
How reproducible:
Most of the times. The issue does not immediately reproduce but can be seen while running system tests.
Steps to Reproduce:
1. Deploy and configure an SNO with Telco DU profile 2. Run system tests which create various workloads and reboot system several times 3. Check linuxptp-daemon logs for time outs oc -n openshift-ptp logs linuxptp-daemon-9fdbz -c linuxptp-daemon-container | grep 'timed'
Actual results:
One or more occurences
Expected results:
No timeouts
Additional info:
PTP master is running on a RHEL bare metal server via ptp4l. The SNO is connected to the same switch as the RHEL bare metal server. Attaching must-gather and PTPConfig.