    Description

      Description of problem:

       When trying to onboard a xFusion baremetal node using redfish-virtual media (no provisioning network), it fails after the node registration with this error:
      
      Normal InspectionError 60s metal3-baremetal-controller Failed to inspect hardware. Reason: unable to start inspection: The attribute Links/ManagedBy is missing from the resource /redfish/v1/Systems/1

      Version-Release number of selected component (if applicable):

          4.14.18

      How reproducible:

          Just add a xFusion baremetal node, specifing in the manifest
      
      Spec: 
        Automated Cleaning Mode: metadata 
        Bmc: 
          Address: redfish-virtualmedia://w.z.x.y/redfish/v1/Systems/1 
          Credentials Name: hu28-tovb-bmc-secret 
          Disable Certificate Verification: true 
        Boot MAC Address: 9C:7D:A3:0E:42:8A 
        Boot Mode: UEFI Online: false 
        Preprovisioning Network Data Name: openstack-hu28-tovb-network-config-secret

      Steps to Reproduce:

          1.
          2.
          3.
          

      Actual results:

          Inspection fails with afore mentioned error, no preprovisioning image is mounted on the hoste virtualmedia

      Expected results:

          VirtualMedia get mounted and inspection starts.

      Additional info:

          

      Attachments

        Activity

          People

            janders@redhat.com Jacob Anders
            rh-ee-afrances Andrea Franceschini
            Jad Haj Yahya Jad Haj Yahya
            Votes:
            1 Vote for this issue
            Watchers:
            4 Start watching this issue

            Dates

              Created:
              Updated: