Bug
-
Resolution: Done-Errata
-
Critical
-
None
-
4.15
Description of problem:
Creating a `BareMetalHost` for an HPE ProLiant DL360 Gen10 Plus doesn't create the corresponding `FirmwareSchema` object.
Version-Release number of selected component (if applicable):
Cluster version is 4.15.0 iLO firmware version is 2.63 Jan 20 2022
How reproducible:
Always
Steps to Reproduce:
1. Create a `BareMetalHost` (and BMC credentials secret) for the machine. 2. Wait for the `FirmwareSchema` to be created.
Actual results:
The `FirmwareSchema` object is never created.
Expected results:
The `FirmwareSchema` object should be created.
Additional info:
See the comments.
- is cloned by
-
OCPBUGS-31686 [4.15] FirmwareSchema not created for HPE iLO5 due to compression disabled
- Closed
- is depended on by
-
OCPBUGS-31686 [4.15] FirmwareSchema not created for HPE iLO5 due to compression disabled
- Closed
- links to
-
RHEA-2024:0041 OpenShift Container Platform 4.16.z bug fix update