      Description of problem:

          DPLL phase offset is stuck on the last value when DPLL enters holdover. 

      Version-Release number of selected component (if applicable):

      latest master    

      How reproducible:

          100%

      Steps to Reproduce:

          1.Setup grandmaster with two-NIC configuration
          2. On the NIC without GNSS module change SMA1 pin direction, so incoming PPS signal stops
          3. The DPLL enters holdover. 

      Actual results:

      The reported DPLL phase offset metric remains stuck on the last value     

      Expected results:

          The reported DPLL phase offset metric jumps to the maximum value

      Additional info:

          

              vgrinber@redhat.com Vitaly Grinberg
              vgrinber@redhat.com Vitaly Grinberg
              Hen Shay Hassid Hen Shay Hassid