Description of problem:
Cannot create SNO spoke cluster with bonded networking.
Version-Release number of selected component (if applicable):
* OpenShift 4.12.24 provisioning on ACM 2.7.6 works, no issues * OpenShift 4.13.10 provisioning on ACM 2.7.6 works * OpenShift 4.12.43 provisioning on ACM 2.9/MCE 2.8 fails * OpenShift 4.14.2 provisioning on ACM 2.9/MCE 2.8 fails
How reproducible:
Reproducible
Steps to Reproduce:
1. Install OpenShift 4.12/4.13 2. Install ACM 2.9 / MCE 2.8 3. Try to install spoke SNO cluster on bare metal with a bonded network.
Actual results:
SNO cluster does not come up after reboot
Expected results:
Installation successful.
Additional info:
PowerEdge R6525 with 2.12.4 BIOS and 7.00.30.00 iDRAC firmware The network cards are NVIDIA ConnectX-6 Lx 2x 25G SFP28 OCP3.0 SFF with 26.36.10.10 firmware.