Description of problem:
We see 19 minutes p99 podready latency for node-density light workload on OVN-IC 120 node environment with Northd Incremental Processing patches i.e OVN_IMAGE - quay.io/itssurya/dev-images:ic-scale-ovnk-v2 CNO image - quay.io/itssurya/dev-images:ic-cno-hack I have got high latency with northd single thread CNO image ( quay.io/itssurya/dev-images:ic-cno-hack-1thread ) as well Slides for this testing https://docs.google.com/presentation/d/16NMDoF52gUb-MybbAtSs16_888nLbshQYCU1Zw3WuvE/edit#slide=id.g24a34730293_0_0 Version-Release number of selected component (if applicable): OCP 4.14 OVN_IMAGE - quay.io/itssurya/dev-images:ic-scale-ovnk-v2 CNO image - quay.io/itssurya/dev-images:ic-cno-hack
Version-Release number of selected component (if applicable):
OCP 4.14 OVN_IMAGE - quay.io/itssurya/dev-images:ic-scale-ovnk-v2 CNO image - quay.io/itssurya/dev-images:ic-cno-hack
How reproducible:
Steps to Reproduce:
1. Deploy 120 node OCP environment on AWS 2. Apply OVN builds 3. Run node-denisty (light) and cluster-density-v2 workloads
Actual results:
p99 pod ready latency is 19 minutes
Expected results:
p99 pod ready latency is 1.77 seconds in OVN_IC without Incremental processing
Additional info:
- relates to
-
OCPBUGS-14286 ovnkube-network-controller-manager high CPU usage in OVNK
- Closed