    Description

      This is a clone of issue OCPBUGS-10884. The following is the description of the original issue:

      Description of problem:

      When ODF StorageSystem CR gets created through the Wizard, the LocalVolumeDiscovery doesn't bring/show devices with mpath type

      Version-Release number of selected component (if applicable):

      OCP 4.11.31

      How reproducible:

      All the time

      Steps to Reproduce:

      1. Get OCP 4.11 running with the LSO and ODF operators
      2. Configure and present mpath devices to nodes used for ODF
      3. Use the ODF wizard to create a StorageSystem object
      4. Inspect the LocalVolumeDiscovery results.

      Actual results:

      There are no devices of mpath type shown by the ODF wizard / LocalVolumeDiscovery CR

      Expected results:

      LocalVolumeDiscovery should discover mpath device type 

      Additional info:

      LocalVolumeSet already works with mpath if you manually define them in .spec or  LocalVolume pointing to mpath devicePaths