Uploaded image for project: 'OCMUI - OpenShift Cluster Manager UI'
  1. OCMUI - OpenShift Cluster Manager UI
  2. OCMUI-3452

HCP wizard - changing subnet removes autoscale validation

XMLWordPrintable

    • Quality / Stability / Reliability
    • False
    • Hide

      None

      Show
      None
    • False
    • OCMUI Center Team Sprint 271, OCMUI Center Team Sprint 272

      Description:

      This was found by Trevor as part of OCMUI-3406. During the HCP wizard, if a user sets the max nodes to be less than min nodes and then later changes a subnet, the validation error goes away even though the number of max node is invalid.

      How to reproduce:

      1. Start the HCP wizard and go to the machine pools step
      2. Select a VPC and add two subnets
      3. Click on the Enable autoscaling checkbox
      4. Set the min nodes to 2 and the max nodes to 1
      5. Verify the "Max nodes cannot be less than min nodes" error is showing
      6. Change one of the machine pools to another subnet
      7. The "Max nodes cannot be less than min nodes" error is no longer showing

      See attached video

      Expected result
      The "Max nodes cannot be less than min nodes" error should always show if the max nodes is less than min nodes.

              kdoberst Kim Doberstein
              kdoberst Kim Doberstein
              Jayakrishnan Mekkattillam Jayakrishnan Mekkattillam
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

                Created:
                Updated:
                Resolved: