      By setting honorTimestamps: true and trackTimestampsStaleness: true We can now get the correct cAdvisor timestamps with the default staleness handling.

      This should be done for both cAdvisor SMs in assets/control-plane/service-monitor-kubelet.yaml and assets/control-plane/minimal-service-monitor-kubelet.yaml.