Uploaded image for project: 'mod_cluster'
  1. mod_cluster
  2. MODCLUSTER-344

No pings when using HTTP connector in default configuration

XMLWordPrintable

      When integrating Undertow, I realized the servers are never removed from m_c when I am using HTTP connector to workaroung broken cping/cpong in Undertow's AJP.

      One needs to configure EnableOptions to enable liveness checking, otherwise the node is never marked as NOTOK (in the larger than ping interval) until next request is received on that node and a client gets an unnecessary error.

        1. access_log
          6 kB
        2. error_log
          375 kB
        3. mod_cluster.conf
          1 kB