Bug
-
Resolution: Done
-
Blocker
-
Logging 5.5.0
-
False
-
None
-
False
-
NEW
-
OBSDA-7 - Adopting Loki as an alternative to Elasticsearch to support more lightweight, easier to manage/operate storage scenarios
-
VERIFIED
-
Log Collection - Sprint 222
collector raises Configuration error if we use CLF to forward logs to default output and and loki is the default store.
Steps to Reproduce:
1. use loki as default storage.
apiVersion: "logging.openshift.io/v1" kind: "ClusterLogging" metadata: name: "instance" namespace: openshift-logging spec: managementState: "Managed" logStore: type: "lokistack" lokistack: name: lokistack-sample collection: type: "vector"
2. use CLF to manage pipeline
apiVersion: logging.openshift.io/v1
kind: ClusterLogForwarder
metadata:
name: instance
namespace: openshift-logging
spec:
pipelines:
name: all-to-defaultES
inputRefs:
- infrastructure
- application
- audit
outputRefs:
- default
Actual result:
oc logs pod/collector-575nm -c collector
2022-07-27T09:07:10.199007Z INFO vector::app: Log level is enabled. level="info"
2022-07-27T09:07:10.199092Z INFO vector::app: Loading configs. paths=["/etc/vector/vector.toml"]
2022-07-27T09:07:10.210016Z ERROR vector::cli: Configuration error. error=Sink "default_infra" has no inputs