Uploaded image for project: 'JBoss Enterprise Application Platform'
  1. JBoss Enterprise Application Platform
  2. JBEAP-9759

It is not possible to set -1 to reconnect attempts attribute of messaging bridge

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Major Major
    • 7.1.0.DR16
    • 7.1.0.DR14
    • Web Console
    • None
    • User Experience
      1. Start EAP
      2. Navigate to Messaging -> Connections
      3. Create new bridge
      4. Try to edit reconnect-attempts on Connection Management tab
      5. Value is not saved

      It is not possible to set -1 value to reconnect-attempts attribute in Web Console which is a valid value for this attribute:

      "The total number of reconnect attempts on the same node the bridge will make before giving up and shutting down. A value of -1 signifies an unlimited number of attempts."

              cmiranda@redhat.com Claudio Miranda
              jkasik@redhat.com Jan Kašík
              Jan Kašík Jan Kašík
              Jan Kašík Jan Kašík
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

                Created:
                Updated:
                Resolved: