Bug
-
Resolution: Done
-
Critical
-
7.4.19.CR1
-
None
With EAP 8.0 Update 3.1 we can see failures of 2 tests in the h2spec TS we use to check that the server behaves according to the HTTP2 protocol standard.
Here are the failing tests:
Hypertext Transfer Protocol Version 2 (HTTP/2) 5. Streams and Multiplexing 5.1. Stream States ... using source address 127.0.0.1:35384r sending RST_STREAM frame × 8: closed: Sends a DATA frame after sending RST_STREAM frame -> The endpoint MUST treat this as a stream error of type STREAM_CLOSED. Expected: GOAWAY Frame (Error Code: STREAM_CLOSED) RST_STREAM Frame (Error Code: STREAM_CLOSED) Connection closed Actual: Timeout using source address 127.0.0.1:35386fter sending RST_STREAM frame × 9: closed: Sends a HEADERS frame after sending RST_STREAM frame -> The endpoint MUST treat this as a stream error of type STREAM_CLOSED. Expected: GOAWAY Frame (Error Code: STREAM_CLOSED) RST_STREAM Frame (Error Code: STREAM_CLOSED) Connection closed Actual: Timeout
The tests send a RST_STREAM frame and then continue with DATA/HEADERS and expect the server to respond with a GOAWAY. But it never does and the connection just times out instead.
This seems to be brought in by the changes from UNDERTOW-2343
- clones
-
JBEAP-27981 [QE](8.0.z) UNDERTOW-2444 - Undertow HTTP2 breaks protocol specification in RST_STREAM scenarios
- Resolved
- depends on
-
UNDERTOW-2444 H2 violation of protocol specification in RST_STREAM scenarios
- Closed