      One interoperability test between EAP 7.4 and RHDG on OpenShift is failing.

      EAP 7 cluster instances are configured to use the remote RHDG cluster for a remote cache.

      During the test one RHDG pod is stopped, in order to verify the "persistence" service fail-over mechanism, which actually takes place.

      Despite this, we noticed an issue: the logs show that one - or more - EAP instances perform a call to Infinispan via HotRod by using an IP which is no longer listed as part of the cluster topology, and after having received the up to date topology.

      This is parallel to JBEAP-25790 for EAP 7.