      1.Start EAP in standalone mode with standalone-full-ha profile
      2.Go to subsystem, logging, handlers , async
      3.Create handler with positive queue length value
      4.Try to edit value to 0 and save
      5.Refresh page and value is not save because 0 is invalid value for queue length

      Show
      1.Start EAP in standalone mode with standalone-full-ha profile 2.Go to subsystem, logging, handlers , async 3.Create handler with positive queue length value 4.Try to edit value to 0 and save 5.Refresh page and value is not save because 0 is invalid value for queue length

      When you create in logging subsystem configuration an async handler with positive queue length value and then try to edit the queue length value to 0 it is successfully saved in web console, not in model, and after refreshing the previous queue length value is shown.
      When you try to set 0 value through CLI with /subsystem=logging/async-handler=sda:write-attribute(name=queue-length,value=0) it shows error

      {
          "outcome" => "failed",
          "failure-description" => "WFLYCTL0117: 0 is an invalid value for parameter queue-length. A minimum value of 1 is required",
          "rolled-back" => true,
          "response-headers" => {"process-state" => "reload-required"}
      }
      