Uploaded image for project: 'Fast Datapath Product'
  1. Fast Datapath Product
  2. FDP-619

[OVN-IC]there are a lot of ic communication packets on the physical interface

    • Icon: Epic Epic
    • Resolution: Unresolved
    • Icon: Normal Normal
    • None
    • None
    • OVN
    • [OVN-IC]there are a lot of ic communication packets on the physical interface
    • False
    • False
    • Hide

      Please mark each item below with ( / ) if completed or ( x ) if incomplete:

      ( ) The acceptance criteria defined below are met.

      Given a basic OVN-IC environment is configured on two systems (az1 and az2) with the topology shown in the description, and Geneve tunnels are set up for interconnection, 

      When the configuration command ovn-nbctl add logical_router_port lr1-ts1 networks "169:254:100::1/64" is removed from the client system,

      Then, the physical interface should not exhibit a high packet rate for IC communication packets and the OVN IC Southbound database (ovn_ic_sb_db.db) should not show continuous significant growth.


      ( ) The epics work is available in a downstream build (nightly/Async or other)


      ( ) All cards under the epic have been moved to Done

      Show
      Please mark each item below with ( / ) if completed or ( x ) if incomplete: ( ) The acceptance criteria defined below are met. Given a basic OVN-IC environment is configured on two systems (az1 and az2) with the topology shown in the description, and Geneve tunnels are set up for interconnection,  When the configuration command ovn-nbctl add logical_router_port lr1-ts1 networks "169:254:100::1/64" is removed from the client system, Then, the physical interface should not exhibit a high packet rate for IC communication packets and the OVN IC Southbound database (ovn_ic_sb_db.db) should not show continuous significant growth. ( ) The epics work is available in a downstream build (nightly/Async or other) ( ) All cards under the epic have been moved to Done
    • rhel-net-ovn
    • 100% To Do, 0% In Progress, 0% Done
    • ssg_networking

      This epic tracks all the effort needed to deliver the solution related to the bug described below.
      config a basic ovn-ic env on two systems,the details are  in attachments

      topo as below:

       

      on the client system, remove this configuration,

      ovn-nbctl add logical_router_port lr1-ts1 networks "169\:254\:100\:\:1/64"

      then capture packets on the physical interface which set the geneve tunnel, we can see about 10000pps packets on it. and the ovn_ic_sb_db.db is increased all the time.

       

      all logs and DBs are in attachment.

      server.tar.xz

      client.tar.xz

       

        1. client.tar.xz
          28 kB
          Ying Xu
        2. server.tar.xz
          587 kB
          Ying Xu
        3. topo.png
          31 kB
          Ying Xu

              xsimonar@redhat.com Xavier Simonart
              rhn-support-yinxu Ying Xu
              OVN
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

                Created:
                Updated: