Uploaded image for project: 'Fast Datapath Product'
  1. Fast Datapath Product
  2. FDP-572

ice/i40e/ixgbe driver: the ovs dpdk vhostuser case cannot got the performance when traffic flows is 1024000

    • Icon: Bug Bug
    • Resolution: Unresolved
    • Icon: Undefined Undefined
    • None
    • None
    • None
    • False
    • Hide

      None

      Show
      None
    • False
    • None
    • rhel-net-ovs-dpdk
    • ssg_networking

      Description of problem:

      Version-Release number of selected component (if applicable):
      rhel9.4 ovs3.1
      rhel8.10 ovs2.17

      How reproducible:

      Run ovs dpdk vhostuser 1queue 4pmd case.
      Steps to Reproduce:
      1. Build ovs dpdk vhostuser pvp topo
      Bridge ovsbr0
      datapath_type: netdev
      Port vhost1
      Interface vhost1
      type: dpdkvhostuserclient
      options:

      {vhost-server-path="/tmp/vhostuser/vhost1"}

      Port dpdk0
      Interface dpdk0
      type: dpdk
      options:

      {dpdk-devargs="0000:07:00.0", n_rxq="1", n_rxq_desc="1024", n_txq_desc="1024"}

      Port ovsbr0
      Interface ovsbr0
      type: internal
      Port dpdk1
      Interface dpdk1
      type: dpdk
      options:

      {dpdk-devargs="0000:07:00.1", n_rxq="1", n_rxq_desc="1024", n_txq_desc="1024"}

      Port vhost0
      Interface vhost0
      type: dpdkvhostuserclient
      options:

      {vhost-server-path="/tmp/vhostuser/vhost0"}

      ovs_version: "3.1.5"

      2. start guest with following xml

      <domain type='kvm'>
      <name>g1</name>
      <memory unit='KiB'>8388608</memory>
      <currentMemory unit='KiB'>8388608</currentMemory>
      <memoryBacking>
      <hugepages>
      <page size='1048576' unit='KiB'/>
      </hugepages>
      <locked/>
      <access mode='shared'/>
      </memoryBacking>
      <vcpu placement='static'>3</vcpu>
      <cputune>
      <vcpupin vcpu='0' cpuset='7'/>
      <vcpupin vcpu='1' cpuset='5'/>
      <vcpupin vcpu='2' cpuset='3'/>
      <emulatorpin cpuset='0,28'/>
      </cputune>
      <numatune>
      <memory mode='strict' nodeset='0'/>
      </numatune>
      <resource>
      <partition>/machine</partition>
      </resource>
      <os>
      <type arch='x86_64' machine='q35'>hvm</type>
      <boot dev='hd'/>
      </os>
      <features>
      <acpi/>
      <apic/>
      <pmu state='off'/>
      <vmport state='off'/>
      <ioapic driver='qemu'/>
      </features>
      <cpu mode='host-passthrough' check='none'>
      <feature policy='require' name='tsc-deadline'/>
      <numa>
      <cell id='0' cpus='0-2' memory='8388608' unit='KiB' memAccess='shared'/>
      </numa>
      </cpu>
      <clock offset='utc'>
      <timer name='rtc' tickpolicy='catchup'/>
      <timer name='pit' tickpolicy='delay'/>
      <timer name='hpet' present='no'/>
      </clock>
      <on_poweroff>destroy</on_poweroff>
      <on_reboot>restart</on_reboot>
      <on_crash>restart</on_crash>
      <pm>
      <suspend-to-mem enabled='no'/>
      <suspend-to-disk enabled='no'/>
      </pm>
      <devices>
      <emulator>/usr/libexec/qemu-kvm</emulator>
      <disk type='file' device='disk'>
      <driver name='qemu' type='qcow2'/>
      <source file='/var/lib/libvirt/images/g1.qcow2'/>
      <backingStore/>
      <target dev='vda' bus='virtio'/>
      <alias name='virtio-disk0'/>
      <address type='pci' domain='0x0000' bus='0x01' slot='0x00' function='0x0'/>
      </disk>
      <controller type='usb' index='0' model='none'>
      <alias name='usb'/>
      </controller>
      <controller type='pci' index='0' model='pcie-root'>
      <alias name='pcie.0'/>
      </controller>
      <controller type='pci' index='1' model='pcie-root-port'>
      <model name='pcie-root-port'/>
      <target chassis='1' port='0x10'/>
      <alias name='pci.1'/>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/>
      </controller>
      <controller type='pci' index='2' model='pcie-root-port'>
      <model name='pcie-root-port'/>
      <target chassis='2' port='0x11'/>
      <alias name='pci.2'/>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/>
      </controller>
      <controller type='pci' index='3' model='pcie-root-port'>
      <model name='pcie-root-port'/>
      <target chassis='3' port='0x8'/>
      <alias name='pci.3'/>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/>
      </controller>
      <controller type='pci' index='4' model='pcie-root-port'>
      <model name='pcie-root-port'/>
      <target chassis='4' port='0x9'/>
      <alias name='pci.4'/>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/>
      </controller>
      <controller type='pci' index='5' model='pcie-root-port'>
      <model name='pcie-root-port'/>
      <target chassis='5' port='0xa'/>
      <alias name='pci.5'/>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x06' function='0x0'/>
      </controller>
      <controller type='pci' index='6' model='pcie-root-port'>
      <model name='pcie-root-port'/>
      <target chassis='6' port='0xb'/>
      <alias name='pci.6'/>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/>
      </controller>
      <controller type='sata' index='0'>
      <alias name='ide'/>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x1f' function='0x2'/>
      </controller>
      <interface type='bridge'>
      <mac address='52:54:00:01:02:03'/>
      <source bridge='virbr0'/>
      <model type='virtio'/>
      </interface>
      <interface type='vhostuser'>
      <mac address='00:de:ad:00:00:01'/>
      <source type='unix' path='/tmp/vhostuser/vhost0' mode='server'/>
      <model type='virtio'/>
      <driver name='vhost' queues='1' rx_queue_size='1024' tx_queue_size='1024' iommu='on' ats='on'>
      <host mrg_rxbuf='off'/>
      </driver>
      <address type='pci' domain='0x0000' bus='0x3' slot='0x00' function='0x0'/>
      </interface>
      <interface type='vhostuser'>
      <mac address='00:de:ad:00:00:02'/>
      <source type='unix' path='/tmp/vhostuser/vhost1' mode='server'/>
      <model type='virtio'/>
      <driver name='vhost' queues='1' rx_queue_size='1024' tx_queue_size='1024' iommu='on' ats='on'>
      <host mrg_rxbuf='off'/>
      </driver>
      <address type='pci' domain='0x0000' bus='0x4' slot='0x00' function='0x0'/>
      </interface>
      <serial type='pty'>
      <source path='/dev/pts/1'/>
      <target type='isa-serial' port='0'>
      <model name='isa-serial'/>
      </target>
      <alias name='serial0'/>
      </serial>
      <console type='pty' tty='/dev/pts/1'>
      <source path='/dev/pts/1'/>
      <target type='serial' port='0'/>
      <alias name='serial0'/>
      </console>
      <input type='mouse' bus='ps2'>
      <alias name='input0'/>
      </input>
      <input type='keyboard' bus='ps2'>
      <alias name='input1'/>
      </input>
      <graphics type='vnc' port='5900' autoport='yes' listen='0.0.0.0'>
      <listen type='address' address='0.0.0.0'/>
      </graphics>
      <video>
      <model type='cirrus' vram='16384' heads='1' primary='yes'/>
      <alias name='video0'/>
      <address type='pci' domain='0x0000' bus='0x05' slot='0x00' function='0x0'/>
      </video>
      <memballoon model='virtio'>
      <alias name='balloon0'/>
      <address type='pci' domain='0x0000' bus='0x06' slot='0x00' function='0x0'/>
      </memballoon>
      <iommu model='intel'>
      <driver intremap='on' caching_mode='on' iotlb='on'/>
      </iommu>
      </devices>
      <seclabel type='dynamic' model='selinux' relabel='yes'/>
      </domain>
      3. start testpmd inside guest
      dpdk-testpmd -l 0-2 -n 1 --socket-mem 1024 – -i --forward-mode=io --burst=32 --rxd=8192 --txd=8192 --max-pkt-len=9600 --mbuf-size=9728 --nb-cores=2 --rxq=1 --txq=1 --mbcache=512 --auto-start

      4. send traffic on T-rex server
      ./binary-search.py --traffic-generator=trex-txrx --frame-size=64 --num-flows=1024000 --max-loss-pct=0 --search-runtime=10 --validation-runtime=60 --rate-tolerance=10 --runtime-tolerance=10 --rate=25 --rate-unit=% --duplicate-packet-failure=retry-to-fail --negative-packet-loss=retry-to-fail --warmup-trial --warmup-trial-runtime=10 --rate=25 --rate-unit=% --one-shot=0 --use-src-ip-flows=1 --use-dst-ip-flows=1 --use-src-mac-flows=1 --use-dst-mac-flows=1 --send-teaching-measurement --send-teaching-warmup --teaching-warmup-packet-type=generic --teaching-warmup-packet-rate=1000

      Actual results:
      1 queue 4 pmd case can got performance result when traffic flows are 1024, 10240 and 102400.
      1 queue 4 pmd case cannot got performance result at last when traffic flows is 1024000.
      ice driver:
      https://beaker.engineering.redhat.com/jobs/9172844
      https://beaker-archive.host.prod.eng.bos.redhat.com/beaker-logs/2024/04/91728/9172844/15964513/176535046/ice_25.html
      i40e driver:
      https://beaker.engineering.redhat.com/jobs/9173722
      https://beaker-archive.host.prod.eng.bos.redhat.com/beaker-logs/2024/04/91737/9173722/15965833/176548779/i40e_25.html
      https://beaker.engineering.redhat.com/jobs/9167969
      https://beaker-archive.host.prod.eng.bos.redhat.com/beaker-logs/2024/04/91679/9167969/15956332/176468152/i40e_25.html

              ktraynor@redhat.com Kevin Traynor (Inactive)
              tli@redhat.com Ting Li
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

                Created: