Uploaded image for project: 'Fast Datapath Product'
  1. Fast Datapath Product
  2. FDP-2936

Test Coverage: Memory regression in ovn25.03-25.03.1-98.el9fdp

    • Icon: Task Task
    • Resolution: Not a Bug
    • Icon: Undefined Undefined
    • None
    • None
    • ovn25.03
    • False
    • False
    • Hide

      ( ) The test coverage is aligned with the epic's acceptance criteria

      Show
      ( ) The test coverage is aligned with the epic's acceptance criteria
    • rhel-9
    • None

      This task is tracking the test case writing activities to cover the bug described below.

       Problem Description: Clearly explain the issue.

      OpenShift has witnessed a ~10% memory regression in ovn-controller and OVS after the minor version bump for OVN.

       Impact Assessment: Describe the severity and impact (e.g., network down,availability of a workaround, etc.).

      Increased memory utilization

       Software Versions: Specify the exact versions in use (e.g.,openvswitch3.1-3.1.0-147.el8fdp).

      ovn25.03-25.03.1-98.el9fdp

        Issue Type: Indicate whether this is a new issue or a regression (if a regression, state the last known working version).

      regression over the previous release ovn25.03-25.03.1-60.el9fdp.

       Reproducibility: Confirm if the issue can be reproduced consistently. If not, describe how often it occurs.

      100%

       Reproduction Steps: Provide detailed steps or scripts to replicate the issue.

      imaximet@redhat.com opened a bug to revert to the older ovn version and we see the memory return to baseline – see https://github.com/openshift/ovn-kubernetes/pull/2900 

       

      Must results showing the before and after the change and revert  are here- https://gist.github.com/jtaleric/1f95e058d69bf27da2d1b00613a1febe 

       

      Each buildURL has the collection of mg and other artifacts in Prow.

       Expected Behavior: Describe what should happen under normal circumstances.

       

       Observed Behavior: Explain what actually happens.

       

       Troubleshooting Actions: Outline the steps taken to diagnose or resolve the issue so far.

       

       Logs: If you collected logs please provide them (e.g. sos report, /var/log/openvswitch/* , testpmd console)

              ovn-qe OVN QE
              jtaleric Joe Talerico
              OVN QE OVN QE
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

                Created:
                Updated:
                Resolved: