Uploaded image for project: 'Fast Datapath Product'
  1. Fast Datapath Product
  2. FDP-2855

Test Coverage: ovs-vswitchd becomes completely unresponsive when setting enable-chassis-as-gw on EDPM node

    • False
    • Hide

      None

      Show
      None
    • False
    • Hide

      ( ) The test coverage is aligned with the epic's acceptance criteria

      Show
      ( ) The test coverage is aligned with the epic's acceptance criteria
    • rhel-9
    • None

      This task is tracking the test case writing activities to cover the bug described below.

      On a EDPM / Compute node, once we do ovs-vsctl set open . external_ids:ovn-cms-options=enable-chassis-as-gw any ovs comand enters deadlock and never returns.
       
      Any ovs commands is stalling and never returns (like ovs-appctl ofproto/list, ovs-vsctl add-br testbr just stuck)

       
      openvswitch3.5-3.5.0-19.el9fdp.x86_64
      ovn24.03-host-24.03.5-98.el9fdp.x86_64

       Every time we set the node as gateway chassis this happens on any of the 3 computes nodes currently deployed.

              ovsdpdk-triage ovsdpdk triage
              nstbot NST Bot
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

                Created:
                Updated: