Uploaded image for project: 'Fast Datapath Product'
  1. Fast Datapath Product
  2. FDP-2001

Test Coverage: [OVN-IC]there are a lot of ic communication packets on the physical interface

    • Icon: Task Task
    • Resolution: Unresolved
    • Icon: Normal Normal
    • None
    • None
    • ovn24.03
    • False
    • Hide

      None

      Show
      None
    • False
    • Hide

      ( ) The test coverage is aligned with the epic's acceptance criteria

      Given a basic OVN-IC environment is configured on two systems (az1 and az2) with the topology shown in the description, and Geneve tunnels are set up for interconnection, 

      When the configuration command ovn-nbctl add logical_router_port lr1-ts1 networks "169:254:100::1/64" is removed from the client system,

      Then, the physical interface should not exhibit a high packet rate for IC communication packets and the OVN IC Southbound database (ovn_ic_sb_db.db) should not show continuous significant growth.

      Show
      ( ) The test coverage is aligned with the epic's acceptance criteria Given a basic OVN-IC environment is configured on two systems (az1 and az2) with the topology shown in the description, and Geneve tunnels are set up for interconnection,  When the configuration command ovn-nbctl add logical_router_port lr1-ts1 networks "169:254:100::1/64" is removed from the client system, Then, the physical interface should not exhibit a high packet rate for IC communication packets and the OVN IC Southbound database (ovn_ic_sb_db.db) should not show continuous significant growth.
    • None

      This task is tracking the test case writing activities to cover the bug described below.

      config a basic ovn-ic env on two systems,the details are  in attachments

      topo as below:

       

      on the client system, remove this configuration,

      ovn-nbctl add logical_router_port lr1-ts1 networks "169\:254\:100\:\:1/64"

      then capture packets on the physical interface which set the geneve tunnel, we can see about 10000pps packets on it. and the ovn_ic_sb_db.db is increased all the time.

       

      all logs and DBs are in attachment.

      [^server.tar.xz]

      [^client.tar.xz]

       

              ovnteam@redhat.com OVN Team
              nstbot NST Bot
              OVN QE OVN QE
              OVN
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

                Created: