Currently the readiness probe (of the guard pod) will constantly fail because the restore pod containers do not have the readyZ sidecar container.
Example error message:
> Oct 16 13:42:52 ci-ln-s2hivzb-72292-6r8kj-master-2 kubenswrapper[2624]: I1016 13:42:52.512331 2624 prober.go:107] "Probe failed" probeType="Readiness" pod="openshift-etcd/etcd-guard-ci-ln-s2hivzb-72292-6r8kj-master-2" podUID="2baa50c6-b5cd-463e-9b35-165570e94b76" containerName="guard" probeResult="failure" output="Get \"https://10.0.0.4:9980/readyz\": dial tcp 10.0.0.4:9980: connect: connection refused"
AC:
- The guard pod does not complain about the missing readyZ anymore